Customization: | Available |
---|---|
After-sales Service: | Online Support |
Warranty: | 12 Months |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Top drive cable include: Power cable, Auxiliary cable, Control cable, Communication cable.
BPM Top Drive Cable
BPM top drive service loop, mainly power cable : auxiliary power cable (12-core auxiliary power cable), control cable (67-core control cable), the market is mainly 12-core and 67 -core, can be manufactured separately, saving cost.
The cable contains the original factory import and domestic, according to customer needs and use location to select the best products.
NOV Top Drive Cable
NOV (varco) top drive service loop power cable : auxiliary power cable (19-core auxiliary power cable), control cable (42-core control cable), including series TDS-9SA, TDS-10SA,TDS-11SA,TDS-8SA.
The cable contains imported and domestic, according to customer needs and use location to select the best products.
TPEC Top Drive Service Loop
TPEC top drive service loop, mainly power cable : auxiliary power cable (31 core auxiliary power cable).
control cable (51-core control cable).
TPEC top drive cable is mainly domestic, internal potting cable fixing glue, according to customer needs and use location to choose the best products.
The interior potting of the travelling cable to fix the cable to prevent friction when the cable comes back to bend, and the two ends are sealed with a new type of high hardness insulation material to prevent water intake. Strict drying treatment should be carried out before potting chemical materials such as epoxy resin and quartz powder, so that bubbles and moisture can not enter the cable plug, and the edge of the lead sheath should be insulated and strengthened.
DAMAGE AND MAINTENANCE - Damage
Analysis on the causes of damage to Auxiliary Power Cable.
1.Mechanical damage, the main reasons are as follows:
1) disassembly and assembly damage: when the equipment is disassembled and disassembled on the spot, the cable is bruised due to human operation factors, and the pulling injury is caused by lifting or excessive speed below. In addition, due to the limitation of the drilling floor area, the cable will sometimes be overbent (the bending radius is less than 36inch) and cause damage.
2) Weather factors damage: due to some working environment natural weather is relatively bad, windy and rainy season, resulting in cable broken;
3) when moving up and down along the guideway under the traction of the tour car, it may rub and hang with the wire rope on the inside of the Derick, so that the rubber of the cable will be worn out, resulting in the short circuit of the cable or other cable faults;
4) Natural aging damage: in the process of normal use, the cable joint operates with load for a long time, resulting in the expansion of insulating glue and the cracking of shell or sheath; Another part of the cable is in the swimming area, which may cause internal fatigue damage due to repeated bending and straightening.
2.Moisture and Aging of Insulation.
The cable plug is not effectively inserted in place, or the sealing ring inside the plug fails because of extrusion or aging, which leads to the water intake of the cable plug. Or drilling platform leakage of mud, production water and a variety of oil traces can easily adhere to the cable and cause cable glue corrosion and moisture; secondly, drilling fluid and various oil products may also cause perforation. The drilling site is generally 24 hours a day, and the top drive cable will continue to operate with load. In addition, with the high temperature and drying of the field working environment, the ionization of the air gap in the cable will cause local overheating and carbonation of insulation, which will lead to the continuous increase of cable operating temperature, and then cause the cable itself to overheat and accelerate the damage of insulation.
3.Terminal reflection.
Because there is no external output reactor at the output end of the frequency converter, the voltage at a certain point of the cable may be several times the normal voltage, and it will also lead to the failure of the cable due to insulation problems.
World famous brands of Top Drive including Varco, Canrig, NOV, BPM, JH, etc.
Top Drive Parts including Gooseneck, saver sub, IBOP, gear, stuffing box, washpipe, cables and service loops, etc.
Lake Petro can supply China made interchangeable parts for above mentioned Top Drive Parts.
Below are pictures of Gooseneck and Flange end for JH Top Drive DQ70, for Russia clients.
If you need any related parts or tools, freely ask me.
Top Drive Brands and some Models
Varco | TDS-8SA, TDS-11SA, etc. |
Canrig | 250ton~750ton |
BPM |
DQ70BSC, etc. |
JingHong (JH, China) | DQ50B, DQ70BS, DQ80BS, etc. |
Tianyi (TPEC, China) | DQ20, DQ40, DQ50, DQ70, DQ 90, etc. |
Other hot sale Top Drive Parts:
Lake Petro company is a professional supplier of various oilfield equipment, including oil drilling and service equipment,oil production equipment,OCTG ,wellhead & downhole tools and spare parts with API certification. Following the principle of "quality first, science and technology innovated, people oriented", every Lake Petro person is sparing no effort to provide the customers with best products and services. Through efforts of Lake Petro staff, our products have already been exported to USA, South America, Africa, Middle East, Russia and some other countries (regions). With super quality, reasonable price and professional service, Lake Petro company has become VIP (assigned) supplier and built strategic partnership with some coutries' national petroleum companies.
How to order?
Please send us your inquiry with detail item description or with Model number.
If there is no packing demand we take it as our regular exported standard packing.
We will offer you an order form for filling. We will recommend you the most suitable model according to information you offered.
You send us your detail requirement, we provide quotation to you.
Can I expect a quality products?
All the production and processing are strictly according to ISO 9001:2008 and API standard. At the same time, mature production technology ensuring the quality satisfy international request. We also welcome the third party inspection, such as BV, SGS and TUV.
The information you may like to know before Payment:
1. Methods of Payment:
T/T (Telegraphic Transfer) or L/C at sight
2. Shipping way
Sample order: we suggest Courier express like DHL/UPS/TNT/FEDEX or by air
Bulk order: we suggest by air or by sea.
3. Quality Control
We have our own experienced QC.
There will be strict inspection and testing for every order before shipping out.